Product characteristics |
Output signal |
analogue signal |
Measuring range |
-1…4 bar |
-14.5…58 psi |
-100…400 kPa |
|
Process connection |
threaded connection Aseptoflex external thread Aseptoflex |
Application |
Special feature |
Gold-plated contacts |
Application |
flush mountable for the food and beverage industry |
Installation |
freely rotatable housing 350° |
Media |
viscous media and liquids with suspended particles; liquids and gases |
Medium temperature [°C] |
-25…125; (145 max. 1h) |
Min. bursting pressure |
100 bar |
1450 psi |
10000 kPa |
|
Pressure rating |
|
Type of pressure |
relative pressure |
No dead space |
yes |
Electrical data |
Operating voltage [V] |
20…32 DC |
Min. insulation resistance [MΩ] |
100; (500 V DC) |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
0.5 |
Switch-on peak current [mA] |
6 |
Switch-on peak current duration [ms] |
30 |
Integrated watchdog |
yes |
Inputs / outputs |
Number of inputs and outputs |
Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
1 |
Output signal |
analogue signal |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4…20, invertible; (scalable 1:4) |
Max. load [Ω] |
300 |
Overload protection |
yes |
Measuring/setting range |
Measuring range |
-1…4 bar |
-14.5…58 psi |
-100…400 kPa |
|
Analogue start point |
-1…3 bar |
-14.5…43.5 psi |
-100…300 kPa |
|
Analogue end point |
0…4 bar |
0…58 psi |
0…400 kPa |
|
In steps of |
0.005 bar |
0.05 psi |
0.5 kPa |
|
Factory setting |
|
ASP = 0.000 bar |
AEP = 4.000 bar |
|
Accuracy / deviations |
Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
Characteristics deviation [% of the span] |
< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
Linearity deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Hysteresis deviation [% of the span] |
< ± 0,15; (Turn down 1:1) |
Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,05; (0…70 °C) |
Temperature coefficient span [% of the span / 10 K] |
< ± 0,15; (0…70 °C) |
Response times |
Damping for the analogue output dAA [s] |
0.1…100 |
Max. response time analogue output [ms] |
40 |
Software / programming |
Parameter setting options |
zero point; span |
Operating conditions |
Ambient temperature [°C] |
-25…80 |
Storage temperature [°C] |
-40…100 |
Protection |
IP 67; IP 69K |
Tests / approvals |
EMC |
EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated |
10 V/m |
EN 61000-4-4 Burst |
2 kV |
EN 61000-4-5 Surge |
0,5/1 kV |
EN 61000-4-6 HF conducted |
10 V |
|
Shock resistance |
DIN IEC 68-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN IEC 68-2-6 |
20 g (10…2000 Hz) |
|
MTTF [years] |
238 |
Mechanical data |
Weight [g] |
32.5 |
Materials |
stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
Min. pressure cycles |
100 million |
Process connection |
threaded connection Aseptoflex external thread Aseptoflex |
Displays / operating elements |
Display |
Display unit |
4 x LED, green |
function display |
alphanumeric display, 4-digit |
measured values |
alphanumeric display, 4-digit |
|
Display unit |
bar; psi; kPa; % of the span |
Remarks |
Remarks |
The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
|
Pack quantity |
1 pcs. |